Detail Product :
Spesification Product :
| Measuring Principle: | Keypad: |
| Transit time difference | 16 Key with tactile action |
| Pipe Size: | Response Time: |
| S Type : 15 mm ~ 100 mm (1/2″ ~ 4″) | Less than 1 second |
| M Type : 50 mm ~ 1000 mm (2″ ~ 40″) | Flow Velocity: |
| L Type : 300 mm ~ 6000 mm (12″ ~ 240″) | 0.01 ~ +/- 32 m/s |
| HS Type : 15 mm ~ 100 mm (1/2″ ~ 4¡¡À) | Resolution: |
| HM Type: 50 mm ~ 1000 mm (2″ ~ 40¡¡À) | 0.0001 m/s |
| Pipe Material: | Ambient Temperature: |
| Cast Iron, Stainless Steel, Ductile Iron | -20 ~ +50 oC |
| Copper, PVC, Aluminum, Fiberglass… etc. | Mounting: |
| Liner Material: | Wall mounting |
| Tar Epoxy, Rubber, Mortar, Polypropylene, | Max. Cable Length: |
| Polystyrol, Polyethylene, Teflon¡ etc | 300 M |
| Display: | Power Consumption: |
| 4 Line LCD with illumination | Less than 2W |
| Flowrate | Power Supply: |
| 5 digit with decimal point | 90 ~ 260Vac 50/60 Hz or 8-36Vdc |
| Totalizer | Data Storage: |
| 8 digit, Forward, Reverse & Net values. | Operation parameters and totalizer |
| Engineer Unit | figures are stored by EEPROM for more |
| M3, Liter, US Gallon, Imperial Gallon, | than 10 years |
| Million Gallon, Cubic Feet, US Barrels, | Output: |
| Imperial Barrels, Oil Barrel | 4-20 mA or 0-20 mA |
| Time Unit | Pulse Output: |
| Second, Minute, Hour, Day | 1- 9999 Hz |
| Other | Data Logger: |
| Velocity, Date, Time, Signal condition. | Limitless overwriting in 64 columns |
| Accuracy: | (Flowrate, totalizer, time, date included) |
| +/- 1% ~ +/- 2% of reading (0.5 ~ 30 m/s) | Alarm: |
| +/- 0.5% of reading (Online calibration) | High/Low with buzzer |
| Repeatability: | Communication: |
| +/-0.2% of reading | RS-232 |
| Temperature Input: | Dimensions: |
| 4-20 mA * 2 points for BTU calculation | 235 * 205 * 95 mm |
| Function | Weight: |
T, Measurements for Thermal Energy |
1.5 Kg |
| Protection Class: | |
| Converter | |
| IP65 | |
| Sensor | |
| IP68 (Submersible) |