Detail Product :
Spesification Product :
| Excitation: | Keyboard: | |
| DC pulsed | 4 external keys for programming | |
| Display: | and display control | |
| 4 lines LCD with back light | Low Flow Cutoff: | |
| Line 1 | 0 to 9.9 % | |
| Date and Time | Data logger Function: | |
| Line 2 | 99times flowrate records for power on/off | |
| 6 digit flowrate | Record Data: | |
| 7 digit energy value | Date/Time when power on/off | |
| Fault code | 99 years flow rate / energy / | |
| Supply temperature | temperature / total flow / total energy | |
| Line 3 | One record data per Hour | |
| 9 digit totalizer for forward / reverse flow | Damping: | |
| 9 digit totalizer for heat / cold energy | 0.1 to 99.9 seconds | |
| Fault code content | Self Diagnosis: | |
| Return temperature | The following error message are | |
| Line 4 | displayed if failure occurs | |
| Differential temperature | – Coil failure | |
| Unit | – Power failure | |
| L/S, L/M, L/H, M3/S, M3/m, M3/H, ML/H, ML/m | – Overanged Output | |
| ML/S, KW, MW, KJ/H, MJ/H, GJ/H, Mcal/H Kcal/H, Cal/H |
– Internal error | |
| Measuring Range: | – Overflow | |
| Min. 0 to 0.15 m/s | – Empty pipe | |
| Max. 0 to 15 m/s | Cable Entry: | |
| Accuracy: | Standard :PG11 Option:1/2″NPTF | |
| +/-0.4% of reading (Velocity >=0.5 m/s) | Protection Class: | |
| +/-0.002 m/s (Velocity < 0.5 m/s) | IP 65 | |
| Repeatability: | Ambient Temperature: | |
| +/-0.1% of reading |
|
|
| Current Output: | Material: | |
| 4-20 mA (Isolated) | Aluminum Alloy | |
| Load | Temperature Input: | |
Max. 600 ![]() |
PT1000W, 2 wire | |
| Pulse output: | Power Supply: | |
| Open collector | 90-260 VAC, 50/60 Hz | |
| Rating | 24 VDC +/- 10% (Option) | |
| 3 to 30 VDC, 20 mA Max. | Power Consumption: | |
| Pulse Rate: | 3-17 W (Dependent on sensor size) | |
| 1)Scale pulse (Pusle/M3, Pulse/L, Other) | Weight: | |
| 2)Frequency: 0-5000 Hz | 1.4 Kg | |
| Communication: | Mounting: | |
| RS 485 (MODBUS Protocol) | Wall mounting | |
| HART signal (Compatible) | Bracket on 2″ pipe | |
| Data Storage: | ||
| Operation parameters and totalizer | ||
| figures are stored by EEPROM for more | ||
| than 10 years |