Detail Product :
- Three line LCD display Flow Rate / Totalizer
- Accuracy of +/-0.2% value of reading
- Bi-directional flow measurement, current and pulse output
- Explosion Proof, Exd(ib)ibqllBT5
- Records up to 99 power on / off time
- MODBUS/HART communication
Spesifications Product :
Excitation: | Keypad: | |
DC pulsed | 3 internal keys for programming | |
Display: | and display control | |
3 lines LCD with illumination | Remote switch instead, no need to open | |
Line 1 | cover | |
11 digit totalizer for forward flow | Low Flow Cutoff: | |
11 digit totalizer for reverse flow | 0 to 9.9 % | |
11 digit totalizer for difference | Data logger Function: | |
Line 2 | 99 times flowrate records for power on/off | |
5 digit flowrate / velocity / % / mA / HZ | Record Data: | |
Line 3 | Date/Time when Power on/off | |
Parameter / Query / Clr tot / Query LOG | Flow rate when Power on/off | |
Alarm, Guidance | Totalizer when Power on/off | |
Unit | Damping: | |
M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH | 0 to 99 Seconds | |
GPM, ML/H, ML/m, ML/sec | Density Setting: | |
Measuring Range: | 0.1 to 9.99 g/cm3 | |
Min. 0 to 0.15 m/s | Self Diagnosis: | |
Max. 0 to 15 m/s | The following error message are | |
Accuracy: | displayed if failure occurs | |
+/-0.2% read-out values (Velocity >=0.5 m/s) | – Coil failure | |
+/-0.001 m/s (Velocity < 0.5 m/s) | – Power failure | |
Repeatability: | – Overanged Output | |
+/-0.05% read-out values | – Internal error | |
Current Output: | – Overflow | |
4-20 mA (Isolated) | – Empty pipe | |
Load | Cable Entry: | |
Max. 600 | Standard :M20 / PG11 Option:1/2″NPTF | |
Pulse output: | Protection Class: | |
Open collector | IP 67, Explosion proof, Exd(ib)ibqllBT5 | |
Rating | Ambient Temperature: | |
3 to 30 Vdc, 20 mA Max. |
|
|
Pulse Rate: | Material: | |
1)Scale pulse (Pusle/M3, Pulse/L, Other) | Aluminum Alloy | |
2)Frequency: 0-5000 Hz | Power Supply: | |
Pulse Width: | 90-260 Vac, 50/60 Hz | |
50% of band width | 24Vdc +/-10% (Option) | |
Alarm: | Power Consumption: | |
High/Low with open collector output | 3-17 W (Dependent on sensor size) | |
Rating | Weight: | |
3 to 30 Vdc, 20 mA Max. | 4.5 Kg | |
Communication: | Mounting: | |
RS 485 (MODBUS Protocol) | Wall mounting | |
HART signal (Compatible) | Bracket on 2″ pipe | |
Data Storage: | ||
Operation parameters and totalizer | ||
figures are stored by EEPROM for more | ||
than 10 years |